抛光工艺对690合金传热管晶间腐蚀指标的影响

    Effect by Buffing Treatment on Intergranular Corrosion(IGC) Property of 690 Alloy Tube for Heat-exchanging Service

    • 摘要: 对时效处理后的690合金传热管,在抛光处理前后分别按65% HNO3浸泡法和电化学再活化法(EPR法)进行晶间腐蚀试验,分析抛光工艺对690合金传热管晶间腐蚀指标的影响。试验结果表明:在65% HNO3浸泡试验条件下,抛光处理对690合金传热管的晶间腐蚀性能无明显影响;在EPR电化学法试验条件下,随着抛光次数的增加,活化电流降低并趋于稳定,而抛光后管材的表面粗糙程度是影响电化学腐蚀性能的主要因素。

       

      Abstract: The 690 alloy tube for heat-exchanging service as aging-treated is subjected to the IGC test with the soaking(65%HNO3)method before buffing,and the electrochemical(EPR)method after buffing in order to investigate how the buffing process affects the IGC property of it. The test result shows that with the soaking (65%HNO3) method,little effect is found,while with the electrochemical(EPR)method,such a fact is identified that along with increasing of the buffing frequency,the activation current strength is reduced and going to be finally stabilized. Also identified via the test is that the surface roughness level of the buffed material plays a major role which affects the electrochemical corrosion property of the tube.

       

    /