20G冷拔高压锅炉钢管中魏氏组织的生成及消除
Development and Elimination of Widmannstatten Structure of Cold-drawn 20G High Pressure Boiler Steel Tube
-
摘要: 魏氏组织是20G冷拔高压锅炉钢管所不允许的异常组织。理论与生产实际分析表明, 魏氏组织产生的根源是成品管正火工艺的控制或操作不当造成的。提出了消除魏氏组织的措施。Abstract: As an abnormal structure, the Widmannstatten structure is impermissible for the cold-drawn 20 G high pressure boiler steel tube. Relevant theoretic analysis and actual manufacturing practice show that the said undesirable structure is mainly caused by improper control or maloperation of normalization treatment of the final tube. Preventive actions for the Widmannstetten structure are proposed.