无张力减径过程中钢管壁增厚试验
EXPERIMENT ON W. T. INCREMENT OF STEEL TUBE DURING NON-STRETCH REDUCING PROCESS
-
摘要: 在Φ100mm自动轧管机组无张力减径过程中,测定了钢管管壁增厚值。测定数据表明:在生产条件下,采用△S=0.0044△D·Sc计算增厚值合理可行;而对于Sc<10mm和15mm>Sc ≥ 10mm的减径管,应对计算增厚值作适当修正。Abstract: Steel tube W. T.increment was measured during the operation of non-stretch reducing mill on the Φ100mm plug pipe-rolling line.The resultant data show that under normal operation conditions, it is logical to calculate the gauge increment with equation:△S=0.0044△D. Sc, and that in case of pipe-reducing with Sc<10mm and 15mm>Sc ≥ 10mm, proper correction should be made to the calculated W.T. increment.