PID Closed-loop Control of Master Cylinder Oil Pressure of Hydrostatic Testing Machine
-
-
Abstract
Discussed is the feasibility for applying the PID close-loop control to the master cylinder oil pressure of the hydrostatic testing machine. Also elaborated are details of the modification of the master cylinder oil pressure of the testing machine’ s oil-water balance system with the PID close-loop control,involving such aspects as the testing machine’ s work flow,electrical control principle,hardware configuration and control process program,etc. Thanks to the modification, both the control accuracy and the water pressure-following response speed of the master cylinder’ s oil pressure system are enhanced so as to get the sealing ring’ s service life 3~4 times longer than before, and thus ensure the consistent operation of the testing machine.
-
-