SONG Lingxi, YANG Xu, HUANG Ying, Zeng Li, HUANG Yun. Analysis and Control of Cause for Defect of Super 13Cr Anti-CO2 Corrosion Oil Tubing as Occurred during Hot-rolling Process[J]. STEEL PIPE, 2017, 46(2): 44-47.
    Citation: SONG Lingxi, YANG Xu, HUANG Ying, Zeng Li, HUANG Yun. Analysis and Control of Cause for Defect of Super 13Cr Anti-CO2 Corrosion Oil Tubing as Occurred during Hot-rolling Process[J]. STEEL PIPE, 2017, 46(2): 44-47.

    Analysis and Control of Cause for Defect of Super 13Cr Anti-CO2 Corrosion Oil Tubing as Occurred during Hot-rolling Process

    • Briefed in the paper are the development background, the manufacturing process flow and the main technical specifications of the super 13Cr oil tubing.The main causes for the typical defects of the said tubing as occurred during piercing and hot-rolling processes are investigated via related physical inspection and chemical analysis as well as metallographic analysis.Accordingly, relevant improvement measures are proposed and taken. Also elaborated here are the physical quality level and the feedback from the field operation of the super 13Cr oil tubing as produced with the improved manufacturing process.The analysis identifies that the existance of ferrite δ is the main cause for the said defect.Therefore ferrite δ will be effectively controlled via actions as proper design of the chemical composition of the 13Cr steel, and strict control of the billet heating temperature.