Geng Zheng, Zhao Dongbin, Zhang Guangjun. MONITORlNG SYSTEM FOR TEMPERATURE AT WELDS OF HI-FREQUENCY WELDED PIPE[J]. STEEL PIPE, 1997, 26(6): 47-50.
    Citation: Geng Zheng, Zhao Dongbin, Zhang Guangjun. MONITORlNG SYSTEM FOR TEMPERATURE AT WELDS OF HI-FREQUENCY WELDED PIPE[J]. STEEL PIPE, 1997, 26(6): 47-50.

    MONITORlNG SYSTEM FOR TEMPERATURE AT WELDS OF HI-FREQUENCY WELDED PIPE

    • With colorimetric pyrometer to measure the weld temperature of the hi-frequency welded pipe, the temperature-measuring signal consistence can be improved to ensure the welding quality. The temperature-monitoring system is capable of adjusting output power of the induction electric source via a digital thyristor trigger circuit designed by the user for temperature adjustment. The said system also employs PID controller for closed-loop control of temperature.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return